Sale!

Emerson Fisher LCP100 | Local Control Panel | ATEX Certified Sourcing

Original price was: $3,777.00.Current price is: $3,666.00.

  1. Housing Material | Glass-filled polyester || Power Options | Switch-selectable External (24 VDC) or Loop Powered (8–20 mA) |

    | Power Consumption | 1.32 W max continuous (External) / 0.126 W max (Multi-drop loop) |

    | Operating Temperature Limits | -40°C to 65°C (-40°F to 149°F) |

    | Max Controller Distance | Up to 314 meters (1,030 feet) via 18 AWG shielded cable |

    | Wiring Terminal Capacity | 14 to 26 AWG (polarity sensitive connections) |

Category: SKU: LCP100 Tag:

Description

1.Unboxing & Physical Snapshot (Dynamic List)

  • Model & Brand: Emerson Fisher LCP100 Local Control Panel
  • Physical Dimensions (Approximate W x H x D): 109.5 mm x 253.1 mm x 127.8 mm (4.3 in x 10.0 in x 5.0 in)
  • Estimated Shipping Weight: 2.2 kg (4.9 lbs) including double-walled containment and anti-vibration cushioning inserts.
  • What’s in the Box: LCP100 filled polyester enclosure assembly, integrated pushbuttons with lockable protective covers, status LED indicator modules, encapsulated internal electronics, and factory documentation packets (cable glands and external mounting brackets sold separately depending on plant procurement options).2.Product Introduction (Randomized Structural Hook)

    Operating directly within hazardous plant zones, this local control panel interfaces closely with safety shutdown valves to manage critical emergency loops. The hardware establishes a secure, operator-accessible staging point near the actuator skid, allowing loop handlers to execute manual trips or diagnostic strokes without navigating to the main control room.

Encapsulated internal circuitry and rugged structural boundaries protect against corrosive chemical washdowns and heavy ambient vibrations common on process skids. Instrument technicians must verify proper sealing of the 3/4-inch NPT or M20 conduit entries during field wiring to maintain the integrity of the protective enclosure.

3.Core Technical Specifications

Parameter Value
Housing Material Glass-filled polyester
Power Options Switch-selectable External (24 VDC) or Loop Powered (8–20 mA)
Power Consumption 1.32 W max continuous (External) / 0.126 W max (Multi-drop loop)
Operating Temperature Limits -40°C to 65°C (-40°F to 149°F)
Max Controller Distance Up to 314 meters (1,030 feet) via 18 AWG shielded cable
Wiring Terminal Capacity 14 to 26 AWG (polarity sensitive connections)
Electromagnetic Emissions Complies with FCC Part 15 / EN 61326-1 Class A
Cable Entry Threads 3/4-inch NPT or M20 conduit connections
  1. Global Compliance & Industry CertificationsSafety instrumented function (SIF) loops require rigorous documentation to satisfy functional safety management audits under IEC 61511. This hardware carries intrinsic safety approvals including ATEX and IECEx (Ex ia IIB T4 Ga) for deployment within Zone 0, 1, and 2 hazardous atmospheres, alongside corresponding North American AEx ratings.

The intrinsic safety rating strictly limits electrical and thermal energy storage, ensuring the panel cannot spawn an incendiary spark during explosive gas events. Verify specific lot certifications and serialized safety manuals directly with the original equipment manufacturer before signing off on final loop commissioning.

5.Long-Term Storage & Asset Preservation Guide (E-E-A-T Goldmine)

Inventory controllers storing this panel in climate-controlled warehouses must still account for environmental aging of polymeric enclosure components and internal terminal blocks. Keep the unit inside its original sealed vapor-barrier bag with silica gel desiccant packs intact to prevent airborne industrial pollutants from tarnishing internal spring-clamp terminals.

Store the assembly on flat shelving away from direct ultraviolet light sources to prevent UV degradation of the glass-filled polyester housing shell. Avoid stacking heavy boxes directly on top of the enclosure to protect the lockable pushbutton shrouds and status indicator lenses from mechanical distortion.

6.Physical Installation Prerequisites

Position the physical housing with the wiring conduit entrances oriented strictly facing downward to prevent moisture ingress and condensation pooling along terminal points. Leave adequate workspace around the perimeter of the panel to allow maintenance technicians to operate the lockable pushbutton covers freely. Bond the internal ground lug directly to the local structural earth ground network using heavy-gauge copper wire to mitigate high-frequency transient surges.

7.Buyer’s FAQ (Logistics & Compliance Focus)

  • What Harmonized System (HS) code applies to international shipments of this control panel?Use HS code 8537.10 (Boards, panels, consoles for electrical control or the distribution of electricity, for a voltage not exceeding 1,000 volts). Cross-reference local customs broker requirements for specific preference criteria.
  • Does the Country of Origin affect regional import compliance?Yes, manufacturing location shifts can trigger different regional preferential tariffs; always inspect the packing slip and nameplate stamp for the precise COO before completing tax filings.
  • Is specialized marine transit insurance necessary for overseas freight dispatch?Procure comprehensive all-risk transit insurance combined with external tilt and shock indicators, given that heavy vibration during ocean freight can compromise internal circuit boards.
  • Does this unit come pre-configured with project-specific valve parameters?The unit ships with factory default settings; configuration wizards resident inside the paired digital valve controller automatically synchronize panel functionality upon initial loop power-up.
    Emerson VE4002S1T2B5 M-series Discrete Output Card
    Emerson 5X00499G01 Ovation Distributed Control System Module Strategies
    Emerson KJ2201X1-BA1 – Vertical I/O Carrier
    EMERSON A6500-UM 9199-00117 – Universal Monitoring Module