Sale!

Bently Nevada 330800-16-00-039-03-02 PROXPAC XL Inventory Strategy

Original price was: $4,500.00.Current price is: $4,377.00.

Parameter: Value
Part Number: 330800-16-00-039-03-02
Probe Option: 16 (3300 XL 8 mm probe with multiple approvals)
Standoff Adapter Option: 00 (No standoff adapter)
Probe Penetration Option: 039 (3.9 inches)
Fittings Option: 03 (Two 3/4-14 NPT fittings, one plug)
Mounting Thread Option: 02 (3/4-14 NPT thread)
Enclosure Material: Glass-reinforced conductive Polyphenylene Sulfide (PPS)
Standard Scale Factor: 7.87 V/mm (200 mV/mil) nominal 
Category: SKU: 330800-16-00-039-03-02 Tag:

Description

Main Body

Evaluating lifecycle metrics for critical turbomachinery asset protection loops demands close attention to exact hardware configurations. The Bently Nevada 330800-16-00-039-03-02 functions as a self-contained PROXPAC XL Proximity Transducer Assembly. Because this integrated device combines a 3300 XL 8 mm eddy-current probe and a Proximitor Sensor directly within a specialized housing, classifying this assembly as a low-priority field instrument will risk extended plant downtime if your machinery protection system loses its vibration loops.

Field data indicates these proximity systems maintain stable scale factors unless the internal oscillator circuitry undergoes severe moisture ingress or physical casing damage. If a module fails during a critical run, international lead time variability can extend replacement windows up to 10 weeks.

Parameter: Value
Part Number: 330800-16-00-039-03-02
Probe Option: 16 (3300 XL 8 mm probe with multiple approvals)
Standoff Adapter Option: 00 (No standoff adapter)
Probe Penetration Option: 039 (3.9 inches)
Fittings Option: 03 (Two 3/4-14 NPT fittings, one plug)
Mounting Thread Option: 02 (3/4-14 NPT thread)
Enclosure Material: Glass-reinforced conductive Polyphenylene Sulfide (PPS)
Standard Scale Factor: 7.87 V/mm (200 mV/mil) nominal 

Operating this component assembly in environments with heavy organic solvent splash degrades the composite thermoplastic enclosure housing. When mounted on fluid-film bearing housings with internal case press pressures exceeding design limits, fluid can migrate past the primary tip seals. This hardware assembly is not recommended for installation where process fluid temperatures continuously exceed 177 °C at the probe tip without secondary thermal tracking.

Quick Conclusions

  • Maintain an active on-site buffer stock of 1 to 2 units per operating turbine or compressor skid.
  • Source only factory-sealed assemblies to ensure the integral internal ClickLoc connection boundaries remain pristine.
  • Establish preferred supplier frame agreements to counter long international OEM procurement timelines.

FAQ

  • Does this model require a separate extension cable between the probe and Proximitor? No, the PROXPAC design mounts the Proximitor sensor directly within the field housing, eliminating the field extension cable layer entirely.
  • Can I replace just the internal 8 mm probe if the tip breaks? Yes, but you must specify an approved replacement probe and use a dedicated connector protector to maintain internal housing seals.