Sale!

Allen-Bradley 1756-RM2 | ControlLogix Redundancy Module

Original price was: $1,500.00.Current price is: $1,488.00.

  • Allen-Bradley 1756-RM2 | ControlLogix Redundancy Module
  • Allen-Bradley 1756-RM2 | Redundancy System Module In Stock
  • Buy Allen-Bradley 1756-RM2 | ControlLogix Controller Redundancy
  • Replacement for 1756-RM2 | Allen-Bradley Redundancy Module
  • Allen-Bradley 1756-RM2 | Tested Refurbished Redundancy Bridge
Category: SKU: 1756-RM2 Tag:

Description

1. At-A-Glance Executive Brief

  • Model: 1756-RM2
  • Brand: Allen-Bradley (Rockwell Automation)
  • Part Type: Redundancy Module (ControlLogix)
  • Lifecycle Status: Active
  • Fiber Interface: SFP-based (LC connectors)
  • System Compatibility: ControlLogix 1756 Redundancy Systems

 

2. Technical Introduction

System uptime is not merely a goal; it is a prerequisite for high-stakes process control where every millisecond of controller downtime incurs significant financial loss.

The 1756-RM2 manages the synchronization of data between primary and secondary ControlLogix controllers, ensuring instantaneous switchover during fault conditions. By maintaining continuous memory and I/O image mapping across redundant chassis, this module eliminates the need for manual controller resets or logic re-synchronization. It offloads the synchronization burden from the controller CPU, providing a dedicated pathway for state-of-the-process data transfer, which keeps your secondary controller in a “ready-to-hot-standby” state.

Engineer’s Takeaway: This module is the singular point of failure prevention for your control loop; prioritize installing tested, high-reliability units to maintain seamless failover integrity.

 

3. Core Technical Specifications

  • Module Type: Controller Redundancy Module
  • Communication Interface: Fiber Optic (via SFP)
  • Redundancy Link Distance: Up to 10 km (depending on SFP used)
  • Slot Width: 1 Standard ControlLogix Slot
  • Current Draw @ 5.1V DC: 1.2 A
  • Current Draw @ 24V DC: 2 mA
  • Power Dissipation: 6.1 W
  • Operating Temperature: 0 °C to 60 °C (32 °F to 140 °F)

 

4. Field Engineer’s Tech Notes

  • Fiber Optic Integrity: The 1756-RM2 relies on clean SFP connections. Before installation, use a fiber inspection scope to check the LC connectors for dust or scratches, as even microscopic debris will trigger “Redundancy Fault” alarms due to attenuation on the sync link.
  • Redundancy Firmware Compatibility: Both the Primary and Secondary chassis must run identical firmware versions. Mismatched firmware will prevent the module from completing the synchronization handshake, leaving your system unprotected and in a “Non-Redundant” state.

 

5. Adaptive QA & Testing Protocol

Our testing sequence for the 1756-RM2 focuses on synchronization reliability. We install the module in a redundant pair test chassis and initiate a continuous data sync cycle. We verify the fiber optic transceiver power output through both SFP ports to ensure the link budget is within spec. We then simulate a hard power-down of the primary controller to confirm the secondary module triggers an immediate, error-free switchover of the control responsibility. Inspection reports confirming successful synchronization and link stability are provided upon request.

 

6. Buyer’s FAQ

  • Does this module come with the required SFP transceivers included? Generally, these are sold as the module core; please specify if you require the matching 1756-RM2 fiber SFP modules at the time of order to ensure matching part compatibility.
  • Is there a difference between the 1756-RM and the 1756-RM2? Yes, the 1756-RM2 is the updated version supporting faster synchronization speeds and specific ControlLogix controller series; verify your current system migration requirements before purchasing.
  • Do you offer expedited shipping for emergency break-fix scenarios? Yes, we offer priority overnight shipping for all in-stock 1756-RM2 modules to ensure your redundant pair is back online as quickly as possible.